DG300-2 (3 phase)

Product Description

The Cat® spark-ignited generator product line for stationary applications feature permanent magnet excitation, amortisseur winding, skewed stator, voltage adjustment through the EMCP controller, Class H winding insulation and 2/3 pitch incorporated.

Generator Set Specifications

Frequency
60 Hz
Natural Gas Rating
300 eKW
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Application
Displacement
864.71in³
Speed
1800 rpm

Engine Specifications

Engine Model
14.2 L Spark - Ignited
Compression Ratio
9.5:1
Fuel System
Electronic
Bore
5.31in
Stroke
6.5in

Generator Set Dimensions

Length
136in
Width
57.6in
Height
66.1in
Weight
6274lb

Standard Equipment

  • Cooling
    • Closed coolant recovery system
    • 50/50 Ethylene glycol antifreeze
    • Factory-installed radiator
    • Standard ambient temperatures up to 50°C (122°F)
    • Radiator and cooling fan complete with protective guards
  • Air Inlet
    • Single element air filter
  • Fuel
    • Low fuel pressure switch
    • Primary and secondary fuel shut-off
    • Fuel pressure test po
    • Dual lock off valves
    • Natural Gas or LP Vapor
    • NPT connection
  • Exhaust
    • Exhaust outlet with 3” pipe
  • Generator
    • Full load capacity alternator
    • Class H insulation material
    • Permanent magnet excitation
    • Matched to the performance and output characteristics of Cat engines
    • Class H insulation material
    • Integrated Voltage Regulator
    • Permanent magnet excitation
    • IP23 Protection
    • Full load capacity alternator
  • Controls
    • EMCP 4.2 Series generator set controller
  • Mounting
    • Vibration isolaton (puck type)
    • Rubber vibration isolators
  • Electric Starting And/or Prelube
    • Engine electrical system
    • Battery cables
    • Solenoid activated starter motor
    • Solenoid activated starter motor
  • Electric Power - Package Serial Number Prefix
    • Battery charging alternator
  • Governor
    • Electronic governor (non adjustable)
  • Control Panel
    • EMCP 4.2 Series generator set controller
  • Starting/charging
    • Batteries with rack and cables
    • 12 volt starting motor

Optional Equipment

  • Starting/charging
    • Charging alternator
    • Battery charger – UL Listed 10 amp
    • Jacket water heater
    • Battery heater
  • General
    • Suitable for Use as Service Equipment (SUSE)
    • UL 2200 package
    • Automatic transfer switches (ATS)
    • Enclosures: sound attenuated, weather protective
    • CSA Certification
  • Generator
    • Anti-condensation heater
    • Shunt trip and auxiliary contact breaker
    • Thermal magnetic or electronic trip MCCBs
    • Oversize and premium generators
    • Excitation: [ ] Permanent Magnet Excited (PM)
    • Anti-condensation heater