Product Description
Producing reliable power of 175 ekW at 60 Hz, our DE200 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.
Generator Set Specifications
- Maximum Rating
- 175 ekW
- Minimum Rating
- 175 ekW
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 220 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C7.1 I-6, 4-Cycle Diesel
- Bore
- 4.1in
- Stroke
- 5.3in
- Displacement
- 427.8in³
- Compression Ratio
- 16.0:1
- Aspiration
- Turbocharged Air To Air Charge Cooled
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length - Maximum
- 130.9in
- Width - Maximum
- 44.6in
- Height - Maximum
- 65.6in
- Dry Weight - Genset (maximum)
- 4257lb
Standard Equipment
- 
                            
                            - Engine
- 
                                    - C7.1, Inline 6 cylinder, 4 stroke diesel
 
 
- 
                            
                            - Control Panels
- 
                                    - GCCP 1.1
 
 
- 
                            
                            - Enclosure
- 
                                    - Cat GC enclosure
 
 
- 
                            
                            - Governor
- 
                                    - Mechanical governor
 
 
- 
                            
                            - Alternator
- 
                                    - A Frame standard alternator
 
 
- 
                            
                            - Fuel Storage
- 
                                    - Single wall 8 hour fuel tank
 
 
- 
                            
                            - Air, Cooling & Exhaust
- 
                                    - Enclosure silencer
 
 
- 
                            
                            - General
- 
                                    - Engine and alternator pre-paint, Caterpillar yellow
 
 
Optional Equipment
- 
                            
                            - Certification
- 
                                    - Certificate of Conformance
- Australia, CIS, Gulf Certification
 
 
- 
                            
                            - Auxiliary Supply Voltage
- 
                                    - 120V
 
 
- 
                            
                            - Alternator Requirements
- 
                                    - Space heater
 
 
- 
                            
                            - Genset Control
- 
                                    - Battery charger
- Panel mounted audible alarm
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Earth fault
- Emergency stop with key
- USB to RS485 Communications device
- Coolant heater
- Low coolant level shutdown
- Battery
- Standby Pack (Smart Jacket water heater, Battery charger)
 
 
- 
                            
                            - Fuel Storage
- 
                                    - Dual wall 8 hour fuel tank
- Single wall tank with containment
- Low fuel level shutdown
- Low fuel level alarm
- High fuel level alarm
 
 
- 
                            
                            - Testing & Packaging
- 
                                    - PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF
 
 
- 
                            
                            - Circuit Breaker
- 
                                    - 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 250A
- 3 Pole Circuit breaker 250A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 630A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 400A
 
 
 
                         
     
                    