Product Description

Producing reliable power from 3150 – 4000 ekW at 60 Hz, our C175-20 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We’ve designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is certified for low fuel consumption, U.S. EPA Stationary Emergency Use only.

Generator Set Specifications

Standby Rating
4000 (no fan)/3900/3620(no fan)/3500 ekW
Prime Power Rating
3600 (no fan)/3500/3300 (no fan)/3180 ekW
Emissions/Fuel Strategy
Low Fuel, Tier 2
Voltage
480 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
4000 ekW
Minimum Rating
3150 ekW

Engine Specifications

Engine Model
C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Bore
6.89in
Stroke
8.66in
Displacement
6456.31in³
Compression Ratio
15.3:1
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Governor Type
ADEM� A4

Generator Set Dimensions

Length - Minimum
261.5in
Length - Maximum
330.6in
Width - Minimum
85.4in
Width - Maximum
127.7in
Height - Minimum
87.6in
Height - Maximum
150.7in
Dry Weight - Genset (minimum)
55100lb
Dry Weight - Genset (maximum)
66200lb

Standard Equipment

  • Air Inlet System
    • 4 x Single element air cleaner canisters with service indicator(s).
  • Control Panel
    • 24 Volt DC operation
    • 4 Programmable relay Inputs
    • 4 Programmable relay output
    • Alarm acknowledge
    • Amps (per phase & average)
    • Auto/start/stop control
    • Coolant temperature
    • DC volts
    • Digital indicators
    • Cat ECS 100
    • Emergency stop
    • Emergency stop pushbutton
    • Engine cool-down timer
    • Engine cycle crank
    • Environmental sealed front face
    • Failure to start (overcrank)
    • Frequency (Hz)
    • High Coolant temperature
    • Lamp test
    • Low coolant level
    • Low oil pressure
    • Oil pressure (psi, kPa or bar)
    • Operating hours
    • Overspeed
    • RPM
    • Speed adjust
    • Text alarm/event descriptions.
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Volts (L-L & L-N)
    • Wall mounted controls:
    • Warning/shutdown Indicators:
  • Cooling System
    • AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
    • Coolant sensors
    • JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
    • SCAC cooling
  • Exhaust System
    • Dry exhaust manifold
    • Dual ANSI 18" / DIN 450 flanges. Shipped loose. Support required from installation
  • Fuel System
    • 10 Micron spin on yype
    • 4 Micron spin on type
    • Engine mounted filters x 3
    • Filters x 3
    • Primary fuel filter water/fuel water separator
    • Secondary/tertiary fuel filters
  • Generators And Attachments
    • 3 Phase brushless
    • 3 Phase voltage sensing
    • 6 Leads
    • Anti-condensation space heater
    • Class H temperature rise at 40C ambient
    • Exciter diode monitor
    • Form wound
    • IEC platinum stator RTDs
    • Min / max exciter limiter
    • NEMA Class H insulation
    • Permanent magnet excitation (PMG)
    • Reactive droop capability
    • RFI suppression
    • Right side extension box, bottom cable entry
    • Salient pole
    • Voltage regulator
  • Governing System
    • ADEM A4
    • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
  • Lube System
    • Fumes disposal
    • Gear type lube oil pump
    • Integral lube Oil cooler
    • Lubricating oil
    • Oil drain lines and valve
    • Oil filter, filler and dipstick
  • Mounting Systems
    • Rails - Engine/generator
    • Rubber anti-vibration mounts - shipped loose
  • Starting / Charging System
    • Batteries and battery rack w/cables
    • Battery disconnect switch
    • Dual 24 volt electric starting motors
  • General
    • Paint - Caterpillar yellow with high gloss black rails
    • Right hand servicing
    • SAE standard rotation

Optional Equipment

  • Air Inlet Systems
    • Single element air cleaner
  • Control Panel
    • EMCP 4.4
    • Controller and MV and HV power connection locations
    • Controller voltage and current sensing groups
    • E-Stop
    • Generator harness
    • Generator temperature monitoring
    • Interconnect harness
    • Load share module
    • Modbus monitoring of packages
    • Speed adjust
    • Vandal proof panel door
    • Annunciator modules
    • Customer interface options
  • Cooling System
    • Fuel cooler
    • Package mounted radiators
    • Remote radiators
  • Crankcase Systems
    • Crankcase ventilation system
    • Explosive relief valves
  • Exhaust System
    • Exhaust collectors/manifold
    • Front housing - Prime or continuous
    • Front housing - Standby or mission critical
    • Mufflers (15, 25 and 34 dBA silencers)
  • Fuel System
    • Primary fuel filter
  • Generator
    • Anti-condensation heater
    • Internal excitation (IE)
    • Oversize and premium generators
    • Permanent magnet excitation (PMG)
  • Generators And Attachments
    • Differential current transformers
    • Generator air cleaner
    • Medium voltage - 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
    • Thermostat for space heater
  • Instrumentation
    • Pyrometer and thermocouples
  • Lube System
    • Drain group oil pans
    • Electric prelube pumps
    • Lube oil heater
    • Lubricating oil
    • Oil filters
  • Mounting System
    • IBC vibration isolators - Shipped loose
    • Rubber anti-vibration mounts
    • Spring type linear vibration isolators
  • Power Termination
    • Circuit breakers, IEC compliant
    • Circuit breakers, UL listed
  • Special Tests / Reports
    • Custom generator TVA report
    • Generator test report
    • Genset fuel consumption test
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
    • Special test charge - Engine only
    • Standard engine test charge
    • Standard genset TVA (Torsional Vibration Analysis) report
  • Starting / Charging System
    • 20 Amp Battery chargers
    • 24 Volt battery set - Dry
    • 24 Volt electric starting motor
    • 35 Amp Battery chargers
    • 50 Amp Battery chargers
    • Air pressure regulator
    • Air starting motor
    • Charging alternators - Dry
    • Jacket water heaters
    • Starter location covers
  • General
    • Barring groups:
    • Control GP - air powered bar group
    • Engine air powered
    • Engine barring group
    • Manual
    • Special paint - 3500