C9 Generator Set

Product Description

Producing reliable power from 230 to 330 kVA at 50 Hz, our C9 diesel generator sets designed to ISO 8528-5 transient response requirements. All C9 generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

Generator Set Specifications

Maximum Rating
330 kVA
Minimum Rating
230 kVA
Emissions/Fuel Strategy
EU Stage IIIA
Voltage
200 to 400 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
4.41in
Stroke
5.87in
Displacement
537.01in³
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
Hydraulic electronic unit injection
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
157in
Width - Maximum
47.5in
Height - Maximum
73.5in

Standard Equipment

  • Air Inlet System
    • Air cleaner, light duty with disposable paper filter
  • Control Panels
    • GCCP 1.3
  • Cooling System
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guard
    • Caterpillar extended life coolant
    • Coolant drain line with valve
  • Exhaust System
    • Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank/base supplied
  • Generators And Generator Attachments
    • 12 Leads
    • Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
    • IP23 Protection
    • Power centre, IP22
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Oil drain valves
    • Lubricating oil
    • Oil cooler
  • Mounting System
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator re-paint, Caterpillar yellow

Optional Equipment

  • Certifications
    • European Certificate for Conformance
    • Global Certification for CIS
  • Air Inlet System
    • Single element air cleaner
  • Circuit Breakers
    • 4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps
  • Control Panels
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
    • Control panel Options: Volt free contacts ; Local alarm horn ; Oil temperature displays
  • Cooling System
    • Radiator duct flange
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosure
    • High ambient sound attenuated enclosure
  • Exhaust System
    • 5 and 6 inch elbow kits
    • 5 - 6 inch flange adaptor
    • Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
    • 6 inch flange
  • Fuel System
    • Integral dual wall fuel tank base
  • Generators And Attachments
    • Permanent magnet excitation (PMG) generator
    • Oversize, AREP, CIP generators
  • Mounting System
    • Narrow skid base
  • Starting / Charging System
    • Jacket water heater
    • 5 Amp single Battery charger
    • Battery disconnet switch