DE110 GC Generator Set (60 Hz)

Product Description

Producing reliable power of 100 ekW at 60 Hz, our DE110 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Generator Set Specifications

Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
18.23:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
108.1in
Width - Maximum
39.3in
Height - Maximum
58.1in
Dry Weight - Genset (maximum)
2932lb

Standard Equipment

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Emergency stop with key
    • Battery charger
    • Earth fault
    • USB to RS485 Communications device
    • Panel mounted audible alarm
    • Earth leakage
    • Volt free contacts for common alarm
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Circuit Breaker
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF