DE350S GC Generator Set

Product Description

The DE350S GC diesel generator sets have been developed for your standby applications. Producing reliable power of 350 ekW at 60 Hz, our C9.3 diesel-powered DE350S GC generator set is designed to ISO 8528-5 transient response requirements

Generator Set Specifications

Maximum Rating
350 ekW
Minimum Rating
350 ekW
Emissions/Fuel Strategy
Low Fuel, R96/EUIIIa
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
4.53in
Stroke
5.87in
Displacement
567.5in³
Compression Ratio
16.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Direct Injection
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
186.7in
Width - Maximum
79.3in
Height - Maximum
84in

Standard Equipment

  • Engine
    • C9.3B, Inline 6 cylinder, 4 stroke diesel
  • Air, Cooling & Exhaust
    • Standard air filter
  • Genset Control
    • GCCP 1.1
  • Governor
    • Adem A4
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Air, Cooling & Exhaust
    • 6" Elbow kit
    • No muffler
    • Single stage air filter
    • 6" Elbow kit
    • 5" Muffler - 10 dBA Attenuation
    • 5-6" Exhaust adapter
    • Dual element air filter
    • 6" Muffler - 25 dBA attenuation
    • 5" Elbow kit
    • Canopy silencer
  • Alternator Requirements
    • IP Standard @ 21 FUW A-Frame
    • Space heater
  • Auxiliary Supply Voltage
    • 240V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Circuit Breaker
    • 4 Pole Circuit breaker 800A
    • 4 Pole Circuit breaker 1250A
    • Shunt Trip
    • Neutral earth link
    • 3 Pole Circuit breaker 630A
    • 3 Pole Circuit breaker 800A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 630A
    • 3 Pole Circuit breaker 1250A
    • Overload via alarm switch on breaker
    • Auxiliary contacts
  • Enclosure
    • Cat GC enclosure
  • Fuel Storage
    • Low fuel level alarm
    • High fuel level alarm
    • Fuel level sender
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment 01
  • Genset Control
    • Coolant heater
    • PLG Cellular 4G E
    • Battery charger
    • PLG Ethernet
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Oil temperature displays
    • Low coolant temperature alarm
    • Voltage adjust potentiometer
    • Speed adjust potentiometer
    • PLG Cellular 4G U
    • Battery