DE400 GC Generator Set

Product Description

The DE400 GC diesel generator sets have been developed for your standby applications. Producing reliable power of 400 kVA at 50 Hz, our C9.3 diesel-powered DE400 GC generator set is designed to ISO 8528-5 transient response requirements

Generator Set Specifications

Maximum Rating
400 kVA
Minimum Rating
400 kVA
Emissions/Fuel Strategy
Non-Certified Emissions
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C9.3B, I-6, 4-cycle diesel
Bore
4.53in
Stroke
5.87in
Displacement
567.5in³
Compression Ratio
16.5:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
Common Rail
Governor Type
ADEM™A6

Generator Set Dimensions

Length - Maximum
104.8in
Width - Maximum
44in
Height - Maximum
69.5in
Dry Weight - Genset (maximum)
5070.6lb

Standard Equipment

  • Engine
    • C9.3B, Inline 6 cylinder, 4 stroke diesel
  • Air, Cooling & Exhaust
    • Standard air filter
  • Genset Control
    • GCCP 1.1
  • Governor
    • Adem A4
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Air, Cooling & Exhaust
    • 6" Elbow kit
    • Dual element air filter
    • 5-6" Exhaust adapter
    • Canopy silencer
    • 5" Elbow kit
    • 6" Elbow kit
    • 6" Muffler - 25 dBA attenuation
    • 5" Muffler - 10 dBA Attenuation
    • Single stage air filter
    • No muffler
  • Alternator Requirements
    • IP Standard @ 21 FUW A-Frame
    • Space heater
  • Auxiliary Supply Voltage
    • 240V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Circuit Breaker
    • 3 Pole Circuit breaker 800A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 1250A
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 800A
    • Overload via alarm switch on breaker
    • Neutral earth link
    • 3 Pole Circuit breaker 1250A
    • Auxiliary contacts
    • Shunt Trip
  • Enclosure
    • Cat GC enclosure
  • Fuel Storage
    • Low fuel level shutdown
    • Fuel level alarms
    • Low fuel level alarm
    • Single wall tank with containment 01
    • High fuel level alarm
    • Dual wall 8 hour fuel tank
  • Genset Control
    • PLG Cellular 4G E
    • Oil temperature displays
    • Coolant heater
    • Battery charger
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • PLG Cellular 4G U
    • Voltage adjust potentiometer
    • Low coolant temperature alarm
    • Speed adjust potentiometer
    • PLG Ethernet
    • Battery