Cat C32 Generator Set (IMO III)

Product Description

Cat C32 Generator Set, IMO III emissions certified (SCR required)

Generator Set Specifications

Minimum Rating
219 ekW
Maximum Rating
940 ekW
Frequency
60hz

Engine Specifications

Configuration
Vee-12, 4-stroke-Cycle-Diesel
Aspiration
Turbocharged-aftercooled aspiration
Bore
5.71in
Stroke
6.38in
Displacement
1959in³
Emissions
IMO III emissions certified (SCR required)
Rated Engine Speed
1500 rpm
Governor
Electronic (A5 ECM)
Refill Capacity
Lube Oil System w/ oil filter change: 146 L (38.5 gal)
Oil Change Interval
750 hrs
Cooling
Heat exchanger, keel or radiator cooled
Generator
SR5 - Form Wound

Generator Set Dimensions

Length
167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum)
Width
59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum)
Height
70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum)
Package Dry Weight
15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum)

Standard Equipment

  • Air Inlet System
    • Separate circuit aftercooled (SCAC)
    • Closed crankcase fumes disposal
  • Control System
    • 24V control system
  • Cooling System
    • Heat exchanger or Keel Cooling
    • Watercooled exhaust manifold and turbocharger
    • Hard seawater lines – no flexible hoses
    • Flanges for cooling connections, ANSI or DIN
  • Fuel System
    • Primary fuel filter with water separator installed on base frame
    • Duplex fuel filters with hybrid fuel lines
  • Generators And Generator Attachments
    • IP23, air cooled, form wound SR5 generator offered in 380, 400, 415 and 690 V
  • Lube System
    • Oil fill, simplex filter and dipstick
  • Mounting System
    • Helical spring/rubber isolated mounting for vibration and structure borne noise reduction
  • General
    • Right or left hand service sides
    • Customer wiring and service tool connector

Optional Equipment

  • Alarm And Protection
    • MGCPIIIB control panel with Cat® Alarm and Protection System
    • IP44 generator protection
  • Exhaust System
    • Muffler
    • Water-in-fuel and exhaust temperature sensors
    • SOLAS approved spray shielding
  • Charging System
    • Charging alternator
  • Fuel System
    • Manual or electric fuel priming pump
    • Fuel cooler
  • Lube System
    • Duplex oil filters
  • Starting System
    • Starting motors – air, electric or redundant