D100 GC Generator Set

Product Description

Producing reliable power of 100 ekW at 60 Hz, our D100 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D100 GC generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.

Generator Set Specifications

Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in³
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical, ADEM™A4

Generator Set Dimensions

Length - Maximum
82.6in
Width - Maximum
43.3in
Height - Maximum
52.9in
Dry Weight - Genset (maximum)
2222lb

Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
    • Air cleaner
  • Cooling System
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Generator
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • IP23 Protection
    • Tower panel, IP22, bottom cable entry
    • 12 Leads
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
  • Starting/charging System
    • Batteries
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Alternator System
    • Anti-condensation heater
    • 3 phase sensing
    • Permanent magnet excitation (PMG)
    • R Frame auxilliary winding
    • Quadrature droop kit
  • Circuit Breakers
    • Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
  • Cooling System
    • Coolant heater
    • Low coolant temperature alarm
    • Low coolant level shutdown
  • Control Panel Options
    • Earth fault (2 wire only)
    • Control panel heater
    • GCCP 1.2 Control panel
    • Volt free contacts
    • Emergency stop with key
    • Voltage adjust potentiometer
    • Overload shutdown via breaker
    • Panel mounted audible alarm
    • Battery charger
    • Earth leakage (2 wire only)
    • Speed adjust potentiometer
  • Enclosures
    • Sound attenuated Level 2 enclosure
  • Fuel System
    • Low fuel level alarm
    • Bunded fuel tank
    • Low fuel level shutdown
    • High fuel level alarm
  • Mounting Options
    • Battery removal
    • Electronic governor
    • Industrial silencer
    • External single point lift - enclosure
    • Silencer installation kit
  • Special Packing/inspectons For Shipment
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
  • General - Accessories / Miscellaneous
    • Packing case - canopied set
    • Packing case - compact set
    • Stone guards/rad trans flange