Product Description
Producing reliable power of 100 ekW at 60 Hz, our D100 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D100 GC generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.
Generator Set Specifications
- Maximum Rating
- 100 ekW
- Minimum Rating
- 100 ekW
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 3
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C4.4, In-line 4, 4-cycle diesel
- Bore
- 4.1in
- Stroke
- 5in
- Displacement
- 269in³
- Compression Ratio
- 16.7:1
- Aspiration
- Turbocharged
- Fuel System
- Common Rail
- Governor Type
- Mechanical, ADEM™A4
Generator Set Dimensions
- Length - Maximum
- 82.6in
- Width - Maximum
- 43.3in
- Height - Maximum
- 52.9in
- Dry Weight - Genset (maximum)
- 2222lb
Standard Equipment
-
- Air Inlet System
-
- Air cleaner; light duty with disposable element
- Air cleaner
-
- Cooling System
-
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
-
- Control Panel
-
- GCCP 1.2 Control panel
-
- Exhaust System
-
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
-
- Fuel System
-
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
-
- Generator
-
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Tower panel, IP22, bottom cable entry
- 12 Leads
- Voltage regulator (single phase sensing)
- Segregated low voltage (AC/DC) wiring panel
-
- Governing System
-
- Mechanical and electrical governing system - model dependent
-
- Lube System
-
- Lubricating oil
- Oil drain line with valve
-
- Mounting System
-
- Termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
-
- Starting/charging System
-
- Batteries
- 24V battery with rack and cables
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
-
- Alternator System
-
- Anti-condensation heater
- 3 phase sensing
- Permanent magnet excitation (PMG)
- R Frame auxilliary winding
- Quadrature droop kit
-
- Circuit Breakers
-
- Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
-
- Cooling System
-
- Coolant heater
- Low coolant temperature alarm
- Low coolant level shutdown
-
- Control Panel Options
-
- Earth fault (2 wire only)
- Control panel heater
- GCCP 1.2 Control panel
- Volt free contacts
- Emergency stop with key
- Voltage adjust potentiometer
- Overload shutdown via breaker
- Panel mounted audible alarm
- Battery charger
- Earth leakage (2 wire only)
- Speed adjust potentiometer
-
- Enclosures
-
- Sound attenuated Level 2 enclosure
-
- Fuel System
-
- Low fuel level alarm
- Bunded fuel tank
- Low fuel level shutdown
- High fuel level alarm
-
- Mounting Options
-
- Battery removal
- Electronic governor
- Industrial silencer
- External single point lift - enclosure
- Silencer installation kit
-
- Special Packing/inspectons For Shipment
-
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
-
- General - Accessories / Miscellaneous
-
- Packing case - canopied set
- Packing case - compact set
- Stone guards/rad trans flange