DE400S GC Generator Set

Product Description

The DE400S GC diesel generator sets have been developed for your standby applications. Producing reliable power of 400 ekW at 60 Hz, our C9.3 diesel-powered DE400S GC generator set is designed to ISO 8528-5 transient response requirements

Generator Set Specifications

Maximum Rating
400 ekW
Minimum Rating
400 ekW
Emissions/Fuel Strategy
Low Fuel, R96/EUIIIa
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
4.53in
Stroke
5.87in
Displacement
567.5in³
Compression Ratio
16.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Direct Injection
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
186.7in
Width - Maximum
79.3in
Height - Maximum
84in

Standard Equipment

  • Engine
    • C9.3B, Inline 6 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Adem A4
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Air, Cooling & Exhaust
    • Standard air filter
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • European Certificates
    • Australia, CIS, Gulf Certification
    • EU Certificate of Conformance (CE)
  • Auxiliary Supply Voltage
    • 240V
  • Alternator Requirements
    • Space heater
    • IP Standard @ 21 FUW A-Frame
  • Fuel Storage
    • High fuel level alarm
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment 01
    • Fuel level sender
    • Low fuel level shutdown
    • Low fuel level alarm
  • Enclosure
    • Cat GC enclosure
  • Genset Control
    • Speed adjust potentiometer
    • Battery charger
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Voltage adjust potentiometer
    • PLG Cellular 4G E
    • Low coolant temperature alarm
    • Battery
    • Oil temperature displays
    • PLG Cellular 4G U
    • Coolant heater
    • PLG Ethernet
  • Circuit Breaker
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 1250A
    • Neutral earth link
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 1250A
    • 4 Pole Circuit breaker 800A
    • Circuit breaker padlock
    • Auxiliary contacts
    • 3 Pole Circuit breaker 800A
    • Shunt Trip
    • 3 Pole Circuit breaker 630A
  • Air, Cooling & Exhaust
    • 6" Elbow kit
    • 6" Elbow kit
    • 5" Elbow kit
    • 5-6" Exhaust adapter
    • Canopy silencer
    • 6" Muffler - 25 dBA attenuation
    • Dual element air filter
    • Single stage air filter
    • No muffler
    • 5" Muffler - 10 dBA Attenuation