G3520H Gas Generator

Product Description

From natural gas to biogas, coal mine gases, or hydrogen fuel blends to support combined heat and power (CHP), emergency power, and local grid support applications, Caterpillar has a wide range of reliable gas power solutions.

Generator Set Specifications

Continuous Rating
2519 / 2500 ekW @ 1.0pf
Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
45.30%
Frequency
50 / 60 Hz
RPM
1500
Frequency
50/60 Hz

Engine Specifications

Engine Model
G3520H
Displacement
5956in³
Aspiration
TA
Bore
6.7in
Stroke
8.5in
Compression Ratio
12.1

Generator Set Dimensions

Length
302in
Width
86in
Height
97in
Dry Weight - Genset
54675lb

Standard Equipment

  • Control Panel
    • EMCP 4.3
  • Air Inlet
    • Two-element single-stage air cleaner with enclosure and service indicator
  • Cooling
    • Engine driven water pumps for jacket water and aftercooler
    • Jacket water and SCAC thermostats
    • ANSI/DN customer flange connections for JW inlet and outlet
  • Circuit Breaker
    • LSI Long-Time, Short-Time, Instantaneous Annunciator
    • Rear-mounted
    • 5000A 3-Pole IEC Rated Circuit Breakers
  • Exhaust
    • Center section cooled turbocharger with Cat flanged outlet
    • Dry exhaust manifolds, insulated and shielded
    • Individual exhaust port and turbocharger outlet wired to Integrated Tmeperature Sensing Module (ITSM) with GECM providing alarms and shutdowns
  • Fuel System
    • Electronic fuel metering valve
    • Throttle plate, 24V DC actuator, controlled by GECM
  • Fuel System
    • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Ignition System
    • Electronic Ignition System (controlled by ADEM A4)
    • Individual Cylinder Detonation Sensitive Timing (DST)
  • Generator
    • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
    • SR4B
    • Crankshaft Vibration Damper and Guard
    • Busbar connections
    • Paint- Caterpillar Yellow except rails gloss black
    • Winding temperature detectors
    • Operation and maintenance manuals
    • Parts book
    • Anti-condensation space heater
    • RH Service
    • SR5
    • Reactive droop
  • Govrerning System
    • ADEM A4 4-20mA (0-5VV) Speed Input

Optional Equipment

  • Air Inlet
    • Mounting Brackets and Piping
    • Air cleaner with precleaner
  • Circuit Breaker
    • MP- Frame 6 Pole Bottom Cable Entry
    • 4000/5000A Neutral Current Transformer Automatic Selection
    • No UV trip or package mounted CB Wiring
    • Frame Mounting
  • Control Panel
    • 16 Point/32 Light Annunciator, Shipped Loose
    • Remote Communications Module (PL1000T, PL1000E)
    • Remote annuciator
    • Local PC Monitorring
    • Discrete I/O Module, 12 Digital Inputs, 8 'Form C' Relay
    • Cat Connect: Ehternet, Satellite, Cell Telematics
    • Engine failure relay
    • Local alarm module
    • Synchronizing module
    • Remote PC Monitorring
  • Cooling
    • Inlet/Outlet connections
    • Coolant level drain line with valves, fan with guard
  • Exhaust
    • Muffler and spark-arresting muffler with companion flanges
    • Flange
    • Elbow
    • Flexible Fitting
    • Exhaust Expander
  • Fuel System
    • Gas Knockdown Regulator
    • Fuel filter
    • Gas pressure regulator
    • Gas shutoff valve 24V, ETR (Energized-To-Run)
  • Generator
    • Bearing temperature detectors
    • Cable access box
    • Low voltage extension box
    • Manual voltage control
    • European bus bar
    • Generator air filter
    • Medium and high voltage generators and attachment
  • General
    • Digital diagnostic tool
    • Special paint order
    • Tool set
    • US AID Emblem
  • Starting/charging
    • Battery with cables and rack (shipped loose)
    • 24V starting motors
    • Jacket water heater
    • 60A, 24V charging alternator (requires engine driven pumps)
  • Grid Code Compliance
    • 60 Hz: USA
    • 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard